A wearable medical device fails in the field for two reasons more often than any other: it falls off, or the skin under it breaks down. Both outcomes trace back to the adhesive, and both are decided by chemistry rather than by patch geometry. Acrylic and silicone adhesives fail in opposite directions, which is why the choice is rarely obvious.
This article compares the two chemistries across a realistic multi-day wear cycle and explains the hybrid constructions that device teams increasingly use to get both behaviours.
Two Chemistries, Two Personalities
Acrylic adhesives are typically formulated with tackifiers and crosslinkers to deliver high initial peel strength and strong shear resistance. They bond quickly, hold firmly, and are easy to coat and convert. Their weakness is that they bond firmly to skin as well as to the device, and that bond grows stronger with time, heat and moisture.
Silicone adhesives, particularly silicone gels, have low surface energy and a soft, compliant modulus. They wet the skin surface rather than locking onto it, which produces a gentle peel and allows removal with less trauma. Their weakness is lower shear resistance and a tendency to leave residue if the formulation is too soft.
The practical consequence is that acrylic protects against falling off and silicone protects against skin damage. A device that needs both usually needs a construction that combines them rather than a compromise between them.
Adhesion Build Across a Wear Cycle
Peel strength measured twenty minutes after application tells you very little about day five. Acrylic adhesives typically show adhesion build: peel force increases over the first 24 to 72 hours as the adhesive wets the skin more completely, then plateaus. On intact skin this is helpful. On skin that is moist or damaged, it becomes a removal problem.
Silicone adhesives build far less. Their peel force stays relatively flat, which means the removal experience on day seven resembles the removal experience on day one. For devices that are replaced weekly by patients at home, that predictability is a clinical benefit, not a comfort feature.
Measuring only initial tack therefore biases selection toward acrylic. The evaluation should include peel at the end of the intended wear period, on skin that has been through normal washing and activity.

Moisture and Maceration
Skin under an occlusive patch loses the ability to evaporate sweat. Moisture accumulates, the stratum corneum hydrates and softens, and the result is maceration: white, fragile skin that adheres poorly and breaks down easily. Acrylic adhesives are usually more occlusive than silicone gels, which are relatively breathable because of their open network structure.
Moisture also changes acrylic performance in a second way. Water uptake plasticises the adhesive, reducing shear resistance. A patch that holds well on a dry arm may lift at the edge after a shower and a workout.
Construction can compensate: breathable carriers, perforations, and adhesive applied as a pattern rather than full coverage all improve moisture vapour transmission. This is why adhesive selection and carrier selection should not be made independently.
Skin Trauma on Removal
Removal trauma is a function of peel force and peel angle, and of how much stratum corneum the adhesive takes with it. Acrylic adhesives with high build can strip corneum on removal, particularly in older patients or on skin that has been under occlusion for a week. Repeated removal at the same site compounds the effect.
Silicone gels peel with low force and tend to leave the skin surface intact. For neonatal, paediatric, elderly and compromised-skin populations, this is often the deciding factor regardless of other performance differences.
Neither chemistry eliminates the need for correct removal technique. A silicone adhesive pulled at ninety degrees still generates peak force at the leading edge; a slow, low-angle peel is a device design and instruction requirement.
Shear, Creep and High-Motion Sites
Shear resistance is where acrylic earns its place. Under sustained load, such as a sensor hanging from a patch on the abdomen, acrylic adhesives resist creep far better than soft silicone gels. A silicone gel patch on a high-motion site can slide, and once the edge lifts, moisture and friction accelerate the failure.
Sites under mechanical load often need an acrylic perimeter with a gentler adhesive over the sensor area, or a reinforced construction where the shear load is carried by the carrier rather than the adhesive.
Hybrid Constructions
Three hybrid approaches are common. Silicone gel island with acrylic perimeter: gentle adhesion over the sensor opening, firm anchorage at the edge where lift begins. Pattern-coated acrylic on a breathable carrier: reduces occlusion and moisture build while retaining shear resistance. Silicone adhesive with a high-cohesion carrier: uses the gentler chemistry but relies on the film to carry mechanical load.
Hybrid constructions are more demanding to convert. Two adhesive zones require registration, separate liner handling, and often two lamination stations. That converts a material decision into a process capability question, which is worth raising with the converter before the design freeze.
Selection Matrix
Choose acrylic-dominant when wear is short, shear load is high, the site is low-motion and skin is intact. Choose silicone-dominant when wear exceeds several days, skin is fragile, removal is frequent or the patient removes the device at home. Choose hybrid when both long wear and mechanical load apply, which describes most CGM and infusion sites.
Sterilisation adds a constraint. Gamma sterilisation can degrade some acrylic formulations; ethylene oxide is generally more compatible with both. Confirm the specific construction, not the chemistry family.
Testing the Decision
Four tests settle most of the argument. Peel at the end of the wear period, not only at application. Shear creep under a representative load for the wear duration. Moisture vapour transmission through the finished construction, not the adhesive alone. And a removal assessment on skin, scored for erythema and corneum loss.
For the diagnostic side of adhesive performance, see improving CGM patch adhesion and wear performance and the custom CGM adhesive patch page.
Frequently Asked Questions
Which adhesive is better for a 14-day CGM patch?
Usually a hybrid: a gentler adhesive over the sensor area and a firmer acrylic perimeter to resist edge lift. Long wear alone favors silicone, but mechanical load usually requires acrylic somewhere in the construction.
Why does acrylic adhesion increase over time?
The adhesive progressively wets the skin surface, which raises peel force over the first day or two before plateauing. On moist or damaged skin, that build becomes a removal difficulty.
Is silicone adhesive breathable enough to prevent maceration?
Silicone gels are relatively open and more breathable than typical acrylics, but breathability of the finished construction also depends on the carrier and whether the adhesive is full-coverage or patterned.
Does sterilisation change the choice?
It can. Gamma sterilisation affects some acrylic formulations more than silicone. The specific construction should be tested with the intended sterilisation method rather than the chemistry family in general.
Can hybrid constructions be die cut reliably?
Yes, but they need registration between adhesive zones, separate liner handling and often two lamination stations. Confirm process capability with the converter before design freeze.
How should peel be measured to compare the two?
At the end of the intended wear period, at a controlled angle and rate, on skin that has been through normal washing. Initial tack alone is not a valid comparison.
Conclusion
Acrylic adhesives protect the device from falling off. Silicone adhesives protect the skin from the device. Wearable programs that need both should design a hybrid and validate it with end-of-wear testing rather than initial tack. The chemistry decision is a wear-cycle decision, and the wear cycle is longer than a bench test.
Leetoya converts silicone, acrylic and hybrid adhesive constructions for wearable and CGM components, including pattern coating and multi-zone lamination. See cleanroom manufacturing for the production environment.